Electrical Insulation Rubber Mat

Price:

/Nos

Material:

Solution:

Stock Status:

GST Tax %:

Color: ,

Country of Origin:

MOQ: 1 Nos

Additional information

Brand

Model Name

Material

PVC

Solution

Insulation

Size

1 Mtr x 2 Mtr

Color

Black, Blue

MOQ

1 Roll

Stock Status

On Order Basis

GST Tax %

Country of Origin

India

Electrical Insulation Rubber Mat

Electrical Rubber Mat Distributor & Supplier In India

Universal Enterprises – We are the leading manufacturer, dealer, wholesaler, supplier and trader of Electrical Rubber Mat, Electrical Rubber Mat, PVC Insulated Rubber Mat, and Rubber Electrical Mat In India, Telangana, Andhra Pradesh, Hyderabad, and Nellore Sri City Tada. Electrical Insulation Mats are used as floor covering by safety-conscious organizations for the protection of workers on high and low-voltage installations auto b66KV ac and 240V dc, where human safety is a prime concern. Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution, or its use.

Electrical Insulated Rubber Mat Description

  • Electrical Insulation Mats are specially designed to be used in front of switchboards and high-voltage equipment.
  • These long-life Electrical Insulation Mats are designed to protect operators from electrical shocks thus acting as personal protection equipment.
  • We offer a range of insulating mats for almost any application.
  • Safety from electrical shock is required for workmen whether they are involved in electricity generation, transmission, distribution, or its use.
  • Electrical Safety Mats are highly recommended for the total safety of workmen from electrical shock when working in or around the environment like High Voltage Panels, Sub-station, Power Transformer Rooms, LT & HT Labs, Near Bus bars, Near Control Panels, Anti-Skid / Flooring, etc.
  • These long-lasting, easy-to-install, clean and maintain mats are resistant to oils, acids, alkalis, and low temperatures and are flame retardant as per the provisions of IS 15652:2006.
  • The coloring agents used are free from any metallic derivatives as specified in IS 15652:2006.
  • These mats are tested in our in-house most modern and updated Quality Assurance facilities ensuring complete safety and adherence to the specifications of each roll and are ready to use.
  • The breakdown voltage is 40 kV for 1 Min.
  • The standard size of 1 Mtr x 2 Mtr.
  • Manufactured in various thicknesses (6 mm to 25 mm) for different voltage systems.

Thickness and Voltage System Chart

PVC Insulated Mats

  • Up to 3.3 kV – 2.0 mm
  • Up to 11 kV – 2.5 mm
  • Up to 33 kV – 3.0 mm

Rubber Mats

  • Up to 11 kV – 6, 8, and 10 mm
  • Up to 22 kV – 12, 15, and 20 mm
  • Up to 33 kV – 25 mm

Two Types of Electrical Mats are available in Industry i.e., Chequered Rubber Mats, and PVC Insulated Mats.

Application of Electrical Insulation Mats

These electrical rubber mats are highly recommended for the total safety of workmen from electrical shock when working in or around environments like:

  1. Panel Board
  2. AC Plant Rooms
  3. Power Transformer Rooms
  4. LT & HT Labs
  5. Generator Rooms
  6. All kinds of Electrical Substations
  7. Lift Machine Rooms
  8. Electrical Panels
  9. X-Ray Plant Rooms
  10. Around Bus Bars

The Insulation Mat for Electrical Purposes is best for the safety of electrical shocks. These are available in compliance with the IS: 5424/84 standards. These electrical insulation anti-skid rubber mats are fire retardant and hard-wearing in use. Generally, the insulation rubber mats are used by the electricians and workers involved in the work of electricity transmission, generation, or distribution. The mats are chequered in design that enables the reduction in sound transmission thereby providing safety from high voltage, power transmission rooms, and sub-stations. Ability to remove moisture and grit from the surface, these insulation mats are also suitable for resilient flooring conditions and pathways.

Properties of Electrical Shock-Proof Rubber Mats

Sl. No. Technical Specification All Classes
1 Composition and Surface Rubber elastomer*, Anti Skid Finish. Macromolecular material returns rapidly to its final dimension by a weak stress and release of the stress.
2 Workmanship Mats shall be free from Harmful physical irregularities
3 Mechanical Puncture Resistance Min. 70N
4 Slip Resistance Test @ force of 70N Maximum 15mm
5 Aging Test at 70 deg cl./168hrs. Puncture Resistance shall be min. 80% of the original value.
6 Flame Retardant Test The flame shall not reach any point on a 50mm circle.
7 Thermal Test (Low Temp. Test) No Crack@100N.
No-Breakdown on specified voltage.
8 Acid Test; H2SO4 For 8hrs. Minimum Retention in Mech. Puncture Test initial value. Min. 75% Retention & No Breakdown on specified Voltage.
9 Oil Test; oil for 2hrs. Min. 75% Retention & No Breakdown on specified Voltage.
Minimum Retention in Mech. Puncture test initial value.

 

Electrical Insulated Rubber Mats in India

PVC Insulated Rubber mats Manufacturer in India

Electrical Panel Board Rubber Mats Manufacturer in Telangana

Electrical Rubber Mat Manufacturer in Hyderabad

Electrical Insulated Rubber Mat Suppliers in Andhra Pradesh

Electrical Rubber Mat Exporter in India

Additional information

Brand

Model Name

Material

PVC

Solution

Insulation

Size

1 Mtr x 2 Mtr

Color

Black, Blue

MOQ

1 Roll

Stock Status

On Order Basis

GST Tax %

Country of Origin

India

Reviews

There are no reviews yet.

Only logged in customers who have purchased this product may leave a review.

Thank You for Enquiry.